TY - JOUR
T1 - An Adaptive Resilient Load Frequency Controller for Smart Grids with DoS Attacks
AU - LU, Kang-Di
AU - ZENG, Guo-Qiang
AU - LUO, Xizhao
AU - WENG, Jian
AU - ZHANG, Yue
AU - LI, Ming
N1 - Publisher Copyright:
© 1967-2012 IEEE.
PY - 2020/5
Y1 - 2020/5
N2 - Load frequency control (LFC) is widely employed to keep smart grids stable and secure. This paper proposes an adaptive resilient LFC scheme for sub-systems of smart grids under denial-of-service (DoS) attacks with energy constraint. Firstly, a resilient triggering communication scheme is introduced, where the triggering condition includes the uncertainty item induced by DoS attacks. Secondly, an adaptive resilient event-triggering LFC scheme is proposed to further reduce the communication burden and defeat the DoS attacks, where the event-triggering parameter can be dynamically adjusted. Third, a stability criterion is derived for Proportional Integral-based LFC systems by employing Lyapunov theory. Finally, to validate the proposed control scheme, case studies are carried out based on three different LFC power generation systems including one-area, two-area and three-area models. The simulation results clearly demonstrate that the proposed adaptive resilient LFC scheme can reduce the communication burden while defeating DoS attacks by comparing with resilient event-triggering LFC scheme and event-triggering LFC scheme in term of defense effect and average triggering period.
AB - Load frequency control (LFC) is widely employed to keep smart grids stable and secure. This paper proposes an adaptive resilient LFC scheme for sub-systems of smart grids under denial-of-service (DoS) attacks with energy constraint. Firstly, a resilient triggering communication scheme is introduced, where the triggering condition includes the uncertainty item induced by DoS attacks. Secondly, an adaptive resilient event-triggering LFC scheme is proposed to further reduce the communication burden and defeat the DoS attacks, where the event-triggering parameter can be dynamically adjusted. Third, a stability criterion is derived for Proportional Integral-based LFC systems by employing Lyapunov theory. Finally, to validate the proposed control scheme, case studies are carried out based on three different LFC power generation systems including one-area, two-area and three-area models. The simulation results clearly demonstrate that the proposed adaptive resilient LFC scheme can reduce the communication burden while defeating DoS attacks by comparing with resilient event-triggering LFC scheme and event-triggering LFC scheme in term of defense effect and average triggering period.
KW - adaptive resilient event-triggering communication
KW - denial-of-service attacks
KW - event-triggering communication
KW - Load frequency control
UR - https://www.scopus.com/pages/publications/85085098797
U2 - 10.1109/TVT.2020.2983565
DO - 10.1109/TVT.2020.2983565
M3 - Journal Article (refereed)
AN - SCOPUS:85085098797
SN - 0018-9545
VL - 69
SP - 4689
EP - 4699
JO - IEEE Transactions on Vehicular Technology
JF - IEEE Transactions on Vehicular Technology
IS - 5
M1 - 9051849
ER -